heating.ampilly.fr

Poêle de masse decision board

AChateau AmpillyRenovation project

Recommended mason

AR Kamnářství

Czech Republic

Hoxter specialistFlies to France?

Selected model

Hoxter HE 37/50G

Masonry heater

AR Kamnářství Hoxter tiled stove realization

Why this choice

  • Proven Hoxter work
  • Builds accumulation radiant stoves
  • 3D design to final realization
  • Good value first-call lead

Do now

  • Send RFQ to AR KamnářstvíUse prepared message
  • Share floor plan and photosLocation, chimney, clearances
  • Confirm travel datesTarget: next available slot
  • Ask for preliminary quoteModel, price, inclusions

Questions to ask

  • Lead time for HE 37/50G build?
  • Total price including travel and install?
  • What is included / excluded?
  • Heating performance in kW?
  • Chimney requirements?
  • Warranty and aftercare?

Red flags

  • Vague answers or delays
  • No clear scope or inclusions
  • Unwilling to visit the site
  • Payment terms unclear
  • No references in France

Reference work - masonry heaters

AR Kamnářství Hoxter tiled stove AR Kamnářství masonry heater reference AR Kamnářství custom heat object

Selected Hoxter-listed mason

AR Kamnářství

Modern Czech stove-building workshop for custom fireplaces, masonry heaters, accumulation radiant builds, tiled stoves and cook-stoves.

Why them

  • Listed in the Hoxter partner map.
  • Own site mentions accumulation radiant builds.
  • They handle first idea, 3D design, and final realization.
  • They show Hoxter/tiled stove references.

Message to send

Hello,

I am looking for a true masonry heater / poele de masse in France, built around a Hoxter HE 37/50G insert.

Can you quote a project in France including:
- Hoxter HE 37/50G
- full accumulation masonry / flue-gas channel system
- transport, travel and lodging
- estimated build time on site
- photos of similar masonry heater / tiled stove projects
- whether you can work with a French fumiste for DTU / insurance compliance

I want a reliable, efficient radiant masonry heater, not a standard fireplace or BLOX unit.

Thank you.

Now

  1. Email AR with the RFQ
  2. Ask for France travel confirmation
  3. Ask for 2-3 comparable builds

Next

  1. Get indicative price range
  2. Confirm French fumiste / DTU path
  3. Request Hoxter HE 37/50G quote

Before deposit

  1. EN 15544 style calculation
  2. Chimney / draft check
  3. Written scope and travel costs

Headless STEP + Rhino inspection

3D object, sections, dimensions.

3D locked Click Unlock 3D to rotate or zoom.
Loading 3D model...

CAD readiness

Ready
Headless OCCT STEP exports, rebuilt Rhino 3DM, official Hoxter insert reference, dashboard GLB
Simulation
31 named BREP bodies, 10 smoke-void solids, 7 mass solids, 7.86 m generated smoke path
Orientation
CAD front/glass axis is +Y; dashboard preview rotates front/glass to the right
Checks
channel area 1.9 x Ø180 outlet, rectangular aspect 1:1, cleanouts at lower turns and upper collector
STEP files
combined all, smoke voids only, mass only, finish/access/datums split for simulation setup
Missing
EN 15544 final sizing, EN 13384 chimney inputs, floor-load data, final mason connection choices
Use now
professional geometry handoff and simulation setup; not final execution CAD

Precision pass 2 dimensions

Hoxter body
605 x 650 x 768 mm source dimensions, imported as Rhino OBJ reference
Fire view
HE 37/50 front glass reference, 370 x 500 mm
Burn chamber
305 x 525 mm manufacturer chamber reference
Connections
Ø180 smoke outlet, Ø150 combustion air inlet
Build layers
split refractory walls, side storage masses, top collector, bench mass, outer reference envelope
Smoke path
orange generated void: outlet plenum, center riser, twin top headers, twin down channels, lower turns, rear collector, final Ø180 exit
Open item
smart CAD seed still needs EN 15544 / mason calculation before construction

Compliance process

  1. Site surveyMeasure chimney, floor structure, air supply, and combustible clearances after the object geometry is frozen.
  2. Appliance dataUse exact Hoxter HE 37/50G technical sheet, outlet, output, temperatures.
  3. Stove calculationDimension the one-off masonry heater with EN 15544 logic.
  4. Chimney calculationRun EN 13384-1 draft / temperature / condensation check.
  5. French executionConduit, tubage, raccordement and workmanship path under NF DTU 24.1.
  6. Sign-offMason/fumiste validates before build; this model is geometry, not certification.

Heater core

True symmetrical contraflow object

Hoxter + rings + side mass
Chimney outlet
Collector
Top transfer header
6-8 rings
Hoxter insert
DownUp
UpDown
Refractory bench + bronze skin

Modelling pipeline

Geometry before physics

Pick a step

Phase 01

Shapr3D source geometry

Build the real stove anatomy as separate bodies before any simulation.

Model
Existing wall, Hoxter insert, ring envelope, side masses, bench, collector, chimney outlet.
Output
Dimensioned blockout with named bodies and first mass envelope.
Check
Firebox, air inlet, outlet, channels, cleanouts, and mass layers remain readable in section.
Risk
Pretty outer masonry hiding impossible internal geometry.